![]() ![]() Make sure the unraid USB is in the machine when you boot up or you wont see it in the bios to select it. You can do this by turning UEFI boot off in the bios and that will then let you set the boot order. You may have to go into the bios and enable USB booting. YOU MUST LET THEM ALL GO THROUGH THE INITIALISATION PROCESS. IMPORTANT: MAKE SURE THAT AFTER YOU HAVE CREATED YOUR VD'S YOU GO OVER EACH OF THEM AND PRESS F2 THEN "START INIT" TO INITIALISE THEM. If you follow this very simple labelling scheme then if drive sdg on unraid experiences issues, then you know that it is VD G in the raid controller that you are dealing with and that corresponds to drive 5.ħ. Unraid VD Physical Drive Slot Information When configuring unraid from the UI, you would designate them to their slots in the same order. The raid controller does not pass the actual drive numbers through to unraid, so if you don't name the drives and assign them in unraid in the same order, it makes fault finding a pigs ear when you have to replace a drive.įor instance, my setup has drives 0 and 1 as SSDs. Your SSD's and HDD's are then b, c, d, e etc. The first one "a" is always the USB stick you have the unraid flashed to. When unraid lauches the drives are named a, b, c etc. I highly suggest giving the VD for drive 0 the name "B", VD for drive 1 the name "C", VD for drive 2 the name "C" etc. If you have an R710 with 8 2.5" drives (like me) then your drives will be numbered 0-7. If you have an R710 with 6 3.5" drives then your drives will number 0-5. Select advanced options and set element size to 64KB, read policy to "adaptive read" and write policy to "write through". Press F2 on the controller and click create new VD.ĥ. Boot the server and enter into the raid configuration utility (usually CTRL+R when prompted).Ģ. You want to assign each drive seperately to its own raid-0 virtual drive.ġ. The first thing you need to do is configure the virtual drives. I just wanted to post the steps I go through in order to turn them into unraid servers for those who were asking, seeing as though I have had a lot of help from the community.ĭell R710's running either PERC H700 or 6i controllers should be able to be setup as an unraid server. I noticed recurring questions about Dell R710 servers and unraid over the past few months and I currently have two in operation, one with Perc 6i controller and one with an H700.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |